Configuration Manager Programming steps | en 31
Bosch Security Systems User Manual 970.129b | V2 | 2014.05
RF detector registering and assigning:
Enter the code number for each transmitter (91, 92, etc.)
Assign a function to each wireless transmitter (81, 82, etc):
– 0 - emergency call with a wireless transmitter
– 1 - emergency call with the Carephone 61/62
– 2 - activity monitor reset with unit feedback
– 3 - sign in / sign out
– 4 - action button
– 5 - external input
– 6 - activity monitor reset without unit feedback
– 7 - connection to an individual phone number value, then
assign the call numbers 1 to 10 to be associated with this
alarm function.
– 8 - output assigned
– 9 - fire alarm
– B - motion detection
– D - extended programming
If you have selected D in steps 81, 82, etc, you can choose the
extended transmitter type (111, 112, etc):
– Panic alarm
– Bogus call alarm
– Stove alarm
– Fall detector
– Bed alarm
– Gas alarm
– CO alarm
– Contact detector alarm
– Temperature alarm
– Flood detector alarm
– Pull switch alarm
– Use the custom alarm type and event handler. See steps
201, 202, etc.
CAUTION!
The setting use the custom alarm type and event handler and
steps 201, 202, etc. must only be used in case of a transmitter
in BS8521 protocol! Otherwise, alarms will not be transmitted!