28 en | Programming steps Configuration Manager
970.129b | V2 | 2014.05 User Manual Bosch Security Systems
44. Gateway (IP Module)
Enter here the IP address of the network gateway in case the Carephone
61/62 is connected through this type of device. It should be written in
numbers without dots, always with 12 digits.
The factory setting is: 192168001001.
45 Automatic test call hours (IP/GSM Module)
Program the interval between automatic test calls of the IP Module or GSM
Module from the Carephone 62/61 to the monitoring centre in hours.
Select from 1 to 999 hours, 0 = off, factory setting = 10
49 Phone number of GSM Module (without country code)
Program the own phone number for the GSM Module to be used for the
Carephone 62/61. Maximum length is 22 digits. If the country code of the
phone number of alarm receiving center and GSM module is the same,
then it must not be part of the phone number. If the country code is
different, then it must be part of the phone number.
47 SIM card PIN Code (GSM Module)
Program the SIM PIN Code for the GSM Module. Max. length is 8 digits.
48 APN Code (GSM Module)
Program the code for the Access Point Name (APN) between 0 and 99.
The default setting is 0.
The APN codes can be found at Section A.2 APN codes, Page 34.
48 Auto provider selection (GSM Module)
Use this option if you wish to activate or deactivate the automatic
selection of the GPRS provider. This is useful to avoid unwanted roaming
costs. Check the tick-box to enable this function.
NOTICE!
Programming steps 42, 43 and 44 are not used when a DHCP
service is enabled (setting in step 41). In DHCP mode, the IP
address, subnet mask and gateway address are all
automatically requested from the local DHCP server.