8.2.6 Location 7 - Remote Lock Indication
This location will display characters
R
L
to indicate that
control over the movements of the camera being viewed
have been locked by a user. Control over this camera is
now possible only by the user who locked the camera, or
has higher priority. If the camera is not locked, the icon is
not displayed. If a user error has occurred, this location
will temporarily hold part of the error number.
8.2.7 Location 8 - Monitor Lock Indication
This location will display characters
M
L
to indicate that
the monitor has been locked by a user. The camera
currently being viewed cannot be changed except by the
user who locked the monitor, or has higher priority. If the
monitor is not locked, the icon will not be displayed. If a
user error has occurred, this location will temporarily
hold part of the error number.
8.2.8 Location 9 - Sequence Type Indication
This location displays the type of sequence currently
loaded on the monitor. An absolute sequence is
indicated by the characters
A
S,
meaning that monitors
programmed in the sequence program refer to the exact
monitor(s) where the sequence may be run. Sequences
created via the system keyboards are always of this type,
so absolute sequences are the only type possible in a base
system. Relative sequences are designated by the
characters
R
S
in this location. These sequences will run
on any monitor or group of monitors, and can only be
programmed via the optional LTC 8059/00 MCS for
Windows or the LTC 8850/00 GUI software on a PC.
8.2.9 Locations 10 and 11 - Sequence Number
The sequence number currently active for the monitor is
displayed here. This is a number between 1 and 60, or 00
to indicate that no sequence is loaded.
8.2.10 Location 12 - Sequence Status Indication
This location indicates the status of the sequence active in
the monitor. Possible character combinations are:
1. ^
R
: the current sequence is sequencing in a
forward direction.
2.
R
V
: the current sequence is sequencing in a
reverse direction.
3. ^
S
: the sequence is stopped, but if started again
would sequence in a forward direction.
4.
S
V
: the sequence is stopped, but if started again
would sequence in a reverse direction.
8.3 Monitor Message
The monitor message is a stationary 12-character title
which may be placed on a monitor instead of the
System Status display. Specific monitor messages can
be programmed from either the keyboard
(see User Function 17 in Section 13) or the optional
LTC 8059 MCS package or the LTC 8850/00 GUI
software.
8.4 Broadcast Message
A message can be sent by the operator of the PC using
the optional LTC 8059 MCS package or the
LTC 8850/00 GUI software to all the monitors in the
system. This message may be up to 24 characters, and
can be used to notify all users at all monitor locations of
important information. The message, along with its
beginning and ending time and date, is also printed on
the logging printer (if one is connected), as well as any
user acknowledgment. The broadcast duration may be set
for 1 to 60 seconds. The message is displayed on a line
by itself.
8.5 Program Prompts
During entry of sequence programming via the keyboard,
the Allegiant system prompts the user on the monitor his
keyboard is currently controlling. The display will return
to its previous form when the user leaves the
programming mode.