11.5.3 Sequence & Display Mode
In the Sequence & Display mode alarm response mode, a monitor pair is used to display alarmed video.
Display Sequence Keyboard Operator
Monitor Monitor Monitor Actions Action
1st Alarm D = Video associated with NONE
Occurs 1st alarm is displayed.
S = Video associated with
1st alarm is displayed.
2nd Alarm D = Video associated with NONE
Occurs 1st alarm is still displayed.
S = Video associated with
1st and 2nd alarms are sequenced.
3rd Alarm D = Video associated with NONE
Occurs 1st alarm is still displayed.
S = Video associated with 1st, 2nd,
and 3rd alarms are sequenced.
D = 1st alarm video is removed. 1st ALARM IS
2nd alarm video is now displayed. ACKNOWLEDGED
S = Video associated with 2nd and
3rd alarms continue to sequence.
D = 2nd alarm video is removed. 2nd ALARM IS
3rd alarm video is now displayed. ACKNOWLEDGED
S = Only video associated with
2nd alarm remains.
Since all alarms have been 3rd ALARM IS
acknowledged, both monitors return ACKNOWLEDGED
to normal operator control.