Bosch LTC 8555 Manual de instrucciones Pagina 46

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 45
EN
|
46
Bosch Security Systems | December 8, 2004
LTC 8100, LTC 8200, LTC 8300 Series | Instruction Manual | Keyboard User Functions
Move the joystick left to blank the left side of the
display from the monitor and right to return it. Refer
to User Function 5 or 25 to verify brightness level.
Press [Enter] to update all system monitors to the
selected format. If using the LTC 8555 Series keyboard,
press [User] to exit.
13.1.28 User Function 27 -
Select Keyboard Login
This function controls the system’s keyboard login
feature. Move the joystick up or down to select the
mode for the system to function in. If the login feature
is enabled (MUST USE KBD PWD is selected), the
system keyboards require each user to login and logoff
the system. All users are required to enter a user
number and correct password to interact with the
system. If the login feature is disabled (NO KBD
PWD LOGIN is selected), system keyboards are
always online with the system.
Once selection is made, exit the User Function mode
and reset the system either via keyboard User Function
15, or by removing and restoring the main AC power
to the system. Once the system has been reset, the
keyboard login function will be active and all system
keyboards will need to be logged in to access the
system.
13.1.29 User Function 28 -
Select Console Login
This function controls the system’s external
Console port login feature. After entering the mode,
move the joystick up or down to select the mode in
which the system should function. If the login feature
is enabled (MUST USE CON PWD is selected), any
external PC or other computing device will be
required to login to communicate with the system.
External computing devices are required to enter a
user number and correct password. If the Console
login feature is disabled (NO CON PWD LOGIN is
selected), the Console port is available for
communication.
Once the selection is made, exit the User Function
mode and reset the system, either via keyboard
User Function 15 or by removing and restoring the
main AC power to the system. Once the system has
been reset, the Console login function is active, and
all external computing devices need to login to access
the system.
13.1.30 User Function 29 -
Reset RS-232 Parameters to Default
This function returns the system’s external
RS-232 ports to a known default state. After entering
the mode, enter a valid password. The system will
reset after placing the RS-232 protocols back to the
default state. Refer to the Section 9, FACTORY
DEFAULT SETTINGS for additional information.
13.1.31 User Function 30 -
Set Console RS-232 Parameters
Priority level 1 users can select the RS-232 baud rate
and handshake options for the system’s Console port,
via this function. Upon entry to this mode, the current
settings are displayed. Move the joystick up/down to
select the baud rate, and left/right to select the
handshake option. After being changed, the port is
also automatically set to eight data bits, no parity, and
one stop bit. Once new settings have been selected,
enter the user password and press [Enter]. If using
the LTC 8555 Series keyboard, press [User] to exit.
13.1.32 User Function 31 -
Set Printer RS-232 Parameters
Priority level 1 users can select the RS-232 baud rate
and handshake options for the LTC 8300 system’s
Printer port, via this function. Upon entry to the mode,
the current settings are displayed. Move the joystick
up/down to select the baud rate, and left/right to select
the handshake option. After being changed, the port is
also automatically set to eight data bits, no parity, and
one stop bit. Once new settings have been selected,
enter the user password and press [Enter]. If using the
LTC 8555 Series keyboard, press [User] to exit.
13.1.33 User Function 32 -
Reserved Function
13.1.34 User Function 33 -
Display User Number and Priority
This function displays the current user’s number and
priority level on the monitor screen. The user number
will be displayed on the top line and the user’s priority
level will be displayed on the bottom line of the
monitor screen. If using the LTC 8555 Series keyboard,
press [User] to exit.