17.0 TROUBLESHOOTING
Allegiant systems are designed to perform reliably for long periods of time. All circuitry consists of state of the art
components designed around a single bay concept. If troubleshooting becomes necessary, follow these guidelines:
Problem Description/Solution
System Checkout
Front panel power LED is not lit. • Check the main AC supply source.
Green STATUS LED on front panel is not blinking
and BATTERY LED is off.
• Remove power from unit for 30 seconds. Apply power and verify that the STATUS
LED is blinking. If still not functional, seek service.
• If Red BATTERY LED is lit, replace microprocessor board batteries. Follow
procedure outlined in Maintenance Information Section.
Keyboard Checkout
No keyboard display indicators. • Check interconnect cable for cut or broken wires between the keyboard and the
main bay and replace cable if necessary.
• Relocate keyboard connector on the bay to another keyboard input port.
• Replace keyboard.
Keyboard indicators lit but keyboard is inoperative. • Verify that the keyboard is loggedon to the system (if logon feature is enabled).
• Check interconnect cable for cut or broken wires between the keyboard and the
main bay and replace cable if necessary.
• Relocate the keyboard connector on the bay to another keyboard input port.
• Replace the keyboard.
Limited keyboard functions. If possible, perform local the keyboard test described in Section 13, KEYBOARD
USER FUNCTIONS to verify operation of all keys. If this local test cannot be performed,
replace the keyboard.
• LTC 8059/00 MCS for Windows package users or LTC 8850/00 GUI software
users should refer to lockout tables to determine if the problem is related to user
restriction tables. If table settings are verified and no discrepancies are found,
replace the keyboard.
Keyboard Joystick not centered. • If the analog joystick of the system keyboard becomes un-centered due to normal
wear, it can be recalibrated. If using the IntuiKey keyboard, go to the Keyboard
Control menu and press Joystick Auto Calibrate. If using the LTC 8555 Series
keyboard, refer to User Function 1 procedure.
Video Monitor Display Checkout
No video display on any monitor. • Verify proper CPU operation as described above under System Checkout.
No video display on some monitors. • Verify that an operational camera is selected on suspect monitors.
• Confirm that the monitor is operational.
• Check the monitor coax connections.
• Verify that the coax connection is to the correct monitor output on the rear of the
bay.
Poor video on monitor. • Check the monitor for proper termination.
• Check operation of a known good camera, directly to monitor.
Partial or no on-screen alphanumeric display. • Check user-selectable brightness feature (via User 5 Function) and then verify that
alphanumeric display has been enabled (via User 6 Function). Position the overlay
with User 4 Function.
Time and Date portion of the on-screen display
alternates with ?? ?? ??, and the LED on the front
panel indicates a low battery condition.
• Replace CPU batteries.