CBC
30-2 Camera Handler Release Notes
Supported Resolution
Model Max Resolution Resolution Options on NVR
MP1A 1280x1024 1280x1024 / 640x512
MP1DN 1280x1024 1280x1024 / 640x512
MP2A 1600x1200 1600x1200 / 800x600
MP2DN 1600x1200 1600x1200 / 800x600
MP3DN 2048x1536 2048x1536 / 1024x768 (For MJPEG – only 1024x768)
MP5A 2560x1920 2560x1920 / 1280x960
MP5DN 2560x1920 2560x1920 / 1280x960 (For MJPEG – only 1280x960)
MP8D-L4 1600x1200 1600x1200 / 800x600
Limitations
Refer to Limitations stated for Arecont Vision as they also apply for CBC products.
• The CBC MP2 model and other CBC models may n
ot be discovered via the auto discovery
feature. The CBC cameras should be added manually.
• Due to a NVR limitation, motion detection only
handles resolutions of up to 1280x960 for
AV1XXX, AV8XXX, AV2100, AV2105 and AV2110, motion detection can only handle resolution
as half.
• Due to a camera limitation, for CBC cameras all MJ
PEG only cameras (Arecont: AVxx00,
AV8180, AV8360 – CBC: MP1A, MP2A, MP5A and MP8D-L4) will stream at a higher FPS
(reaching max FPS) when setting to 15FPS. FPS of 14 and lower are not affected by this issue.
• When upgrading to latest camera handler pack, note that the parameters of video streams may
b
e changed to the default values. It is recommended to recheck video codec parameters when
upgrading or restoring configuration backups.
Known Issues
Refer to Known Issues stated for Arecont Vision as they also apply for CBC products.
• Live view and playback streaming (instant playba
ck) on the NVR does not "pace" delivery of
large amounts of data well, causing overflows in network buffers at the VEclient. This issue is
more noticeable when using higher bitrate cameras and will cause skipping in live video and
playback on the VEclient. For video retrieval on higher bitrate cameras it is advisable to search
and retrieve the clip, this will display the recorded video without this issue.
• NVR receiving H.264 with timesta
mp prior to last one received. This is a firmware issue. Beta
firmware has been received from Arecont and resolved the issue, awaiting formal release
(Arecont Ticket: TECHSUP: 15516).