Bosch SF8172V Especificaciones Pagina 55

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 175
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 54
American Dynamics Fixed Camera (Illustra 400 series)
20-2 Camera Handler Release Notes
To achieve optimal H.264 Motion Detection results, the recommended settings are:
Stream 1 is H.264, 30fps, D1 or D2 resolution, default quality
Stream 2 is MJPEG, 7 fps, CIF, default quality
For some properties’ values are retrieved from camera itself (e.g. resolution, quality), that results
in that when the user adds the camera, the return value is not the default value defined in the
NVR, but the actual value in camera.
VideoCodecKeyFrameInterval is not supported by the camera handler, but the user can change
it from the camera web page.
For AudioInputVolume, the microphone input and line-in input have different ranges.:
Microphone input:
A setting of ‘low (1)’ is 20dB
A setting of ‘high (10)’ is 26 dB
Line-in:
A setting of ‘low (1)’ is 6 dB
A setting of ‘high (10)’ is 18dB.
Due to camera internal resource contention, changing the resolution quality or bit rate may affect
the frame rate performance. Please refer to camera limitation.
Changing the video codec/audio codec may cause the RTSP service in the camera to stop, and
the video/audio streaming to stop working, the workaround is to reboot or power cycle the
camera
With camera firmware v2.20, the FPS selections for the MJPEG codec from the camera web
GUI shows only "3,5,7,10,12,15,30" for NTSC and “3,5,7,10,12,15,25" for PAL. This, however,
does not affect the FPS selections from the VideoEdge client, which remain supporting 1 - 30 for
NTSC and 1-25 for PAL.
To meet the single stream fps, the user can enable dual stream on NVR, configure the stream
codec/resolution/fps/quality for Stream 1 and then configure Stream 2 to lowest
resolution/fps/quality. Once Stream 2 is configured the user can disable Stream 2 on the NVR.
Alternatively the user can access the camera’s web GUI settings to change stream 2 to the
lowest/resolution/fps/quality.
Illustra400 Camera will be ‘Unknown’ in NVR camera list after rebooting the NVR while the
camera is offline. The workaround is to first create a password group with the password “9999”,
then add the Illustra 400 camera with this new group, not the default group.
Please refer to the AD Illustra 400 Camera Release Notes for additional information.