K2200 Series | Installation Guide | 1.0 Introduction EN | 6
Bosch Security Systems | 7/03 | 17375 1.3 / 46513C
1.5 Listings and Approval
1.5.1 FCC Notice
This equipment generates and uses radio frequency
energy. If not installed and used in accordance with
the manufacturer's instructions, it may cause
interference to radio and television reception. It has
been tested and found to comply with the
specifications Subpart F of Part 15 of FCC rules for
Field Disturbance Sensors. If this equipment causes
interference to radio or television reception - which
can be determined by turning the equipment on and
off - the installer is encouraged to correct the
interference by one or more of the following
measures:
1. Reorient the antenna of the radio/television,
2. Connect the AC power cord to a different outlet
so the control panel and radio/television are on
different branch circuits,
3. Relocate the control panel with respect to the
radio/television.
If necessary, the installer should consult an
experienced radio/television technician for additional
suggestions, or send for the "Interference Handbook"
prepared by the Federal Communications
Commission. This booklet is available from the
U.S. Government Printing Office,
Washington D.C. 20402,
stock no. 004-000-00450-7.
FCC Registration Number: IDHM32Y6K2000
1.5.2 UL Listing
UL 294 - Access Control System Units
When installing the K2200 series
controllers the following should be noted:
1.5.3 HEALTH AND SAFETY
It must also comply with any local Fire, Health and
Safety regulations. A secured door that may be part
of an escape route from an area must be installed
with:
A fail-safe lock (A). So that the door will
be released if the power fails. Ideally a
magnetic lock should be used as these
are less likely to jam or seize.
A normally-closed break-glass or manual
pull (B) in the lock supply wiring. So that
in an emergency the fail-safe lock can be
immediately powered down.
Figure 1: Failsafe Lock Wiring
B
A
The controller must be grounded.
Disconnect both ac and battery power supply before
working on the controller.
1.5.4 CABLING
The cabling used in the Readykey access control
systems (six wire bus, reader cables, etc.) are not
prone to electrical interference. However, you should
avoid routing cable close to heavy load switching
cables and equipment. If this is unavoidable, cross
the cable at right angles every 3.3 to 6.6 ft (1 to 2 m)
to reduce the interference.