Bosch AMAX panel 4000 EN Guía de instalación Pagina 113

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 176
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 112
Domestic Telephone Number 4 1666 - 1681 15
See Telephone Programming Parameters
If the default 15 is set to the initial digit of the telephone number, domestic telephone alarm
function is disabled; If set to other positions, it marks the end of the telephone number.
Telephone Programming Parameters
Telephone Number
Required
Programming Input
Key
Telephone Number
Required
Programming Input
Key
0 0 7 7
1 1 8 8
2 2 9 9
3 3 * 11
4 4 # 12
5 5 4 seconds pause 13
6 6 15 15
Table 9.1: Telephone Programming Parameters
Zone Programming
Zone Functions
The system supports up to 64 zones. Each zone can select one of 16 zone functions as well as
Areas and modules.
Address 0210 - 0361
Zone Function # 00 Address Default
Zone Type 0210 - 0211 0 0
Force Arm / Zone Bypass 0212 3
VDS-A EN=0/2
Silent Alarm / Chime Mode 0213 0
VDS-A EN=0/2
Zone Pulse Count 0214 0
VDS-A EN=0
Zone Lockout 0215 3
Zone Tamper (DEOL) 0216 1
Zone Status Report 0217 6
VDS-A EN=1/5/6/7
Unverified Alarm Report / Cross Zone 0218 0
VDS-A EN=0
Domestic No. 0219 0
Zone Function # 01 Address Default
Zone Type 0220 - 0221 0 1
Force Arm / Zone Bypass 0222 3
VDS-A EN=0/2
Silent Alarm / Chime Mode 0223 0
VDS-A EN=0/2
9.2
AMAX panel 4000 / AMAX panel 4000
EN
Programming | en 113
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112
Vista de pagina 112
1 2 ... 108 109 110 111 112 113 114 115 116 117 118 ... 175 176

Comentarios a estos manuales