Keypad Indicators
Keypad indicator
icons
Status Definition
1 2 3 ….
ZONE (1-8)
on Zone is triggered.
off Zone is normal.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Zone was alarmed or is in alarm
status.
Slow flash (1 second lights on/1
second lights off)
Zone is manually bypassed or
interior Zone is in STAY ARM
mode.
AWAY
on System is armed in AWAY mode.
off System not armed in AWAY mode.
Slow flash (1 second lights on/1
second lights off)
Exit time.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Programming mode or Code
function mode. STAY indicator
flashes simultaneously.
STAY
on System is armed in STAY mode.
off System not armed in STAY mode.
Slow flash (1 second lights on/1
second lights off)
Exit time.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Programming mode or Code
function mode. AWAY indicator
flashes simultaneously.When
bypass function is performed, the
STAY indicator only flashes.
MAINS
on AC main power is normal.
Slow flash (1 second lights on/1
second lights off)
AC main power supply failed.
FAULTS
on System fault or Tamper condition
is present.
off System is in normal status.
Flashes System fault or Tamper condition
must be acknowledged.
on System is disarmed.
AMAX panel 4000 / AMAX panel 4000
EN
Keypad Usage and Operations | en 157
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112