  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 69
3. When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
Printer Missing
Condition:
No communication with printer if printer is enabled and the DX4010 is normal.
Restore:
Communication with printer and DX4010 are normal and fault is reset.
Supervise:
1. Report the printer missing fault to configured destination when the fault is detected.
2. Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
3. When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
Printer Fault
Condition:
The printer is abnormal (e.g. printer no paper/printer buffer is overflow/...) if printer is enable
and the DX4010 is normal.
Restore:
The printer and DX4010 are normal and fault is reset.
Supervise:
1. Report the printer error to configured destination when the fault is detected.
2. Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
3. When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
RF Receiver Failure
RF Receiver 1 Fault
Condition:
The receiver is abnormal (e.g. RF micro is removed/hold RF micro in reset/...) if wireless
module is enabled.
Restore:
Communication with receiver is normal and wireless module is enabled and fault is reset.
Supervise:
1. Report the receiver fault to configured destination when the fault is detected.
2. Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
3. When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
RF Receiver 1 Missing
Condition:
1. No communication with receiver if wireless module is enable.
2. Any RF zone or repeater or keyfob is configured but the wireless module is disable.
Restore:
Communication with receiver is normal and wireless module is enable and fault is reset.
Supervise:
1. Report the receiver missing fault to configured destination when the fault is detected.
2. Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
70
en | Settings
AMAX panel 4000 / AMAX panel 4000
EN
2013.07 | 03 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH