Output Options
The Value Ranges of Output Programming Options
Output Event Type Description Output Area / Zone
Output
Event
0 Not Used No
1 System Disarmed 0 = All Areas
1 – 16 = Areas 1 - 16
2 System Armed
3 System Alarm 0 = Any Area,
1 - 16 = Areas 1 - 16
4 System Alarm (audile and silent)
5 External AWAY Siren
6 External STAY Siren
7 Internal Siren
8 Internal Siren with tamper
9 Entry/Exit Delay Warning 1 - 16 = Areas 1 - 16
10 Telephone Line Fault
11 AC Power Supply Fault
12 Low Battery
13 Tamper 0 = Any Area,
1 - 16 = Areas 1 - 16
14 External Fault
15 All Faults
16 Fire Alarm 0 = Any Area,
1 - 16 = Areas 1 - 16
17 Fire Reset
18 AWAY Armed 0 = All Areas
1 - 16 = Areas 1 - 16
19 STAY Armed
20 Reset *1 0 = Any Area
1 - 16 = Areas 1 - 16
21 Follow Zone Event Zone Number 1 - 64
22 RF Keyfob button 3 (Garage Door) 0 = Any Area,
1 - 16 = Areas 1 - 16
23 RF Keyfob button 4 (light)
24 Chime Indication *1
25 Verfied Alarm
26 Unverfied Alarm
27 Technical Alarm
28 Bypassed Zone
29 Ready to Arm 0 = All Areas 1 - 16 = Areas 1 - 16
7.3.3
AMAX panel 4000 / AMAX panel 4000
EN
Settings | en 63
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112