2 - System Armed 0=all areas, 1-16 = Areas1-16
The output operates on below conditions:
1. System armed after system reset
System operated the arm command and until system is armed. (When system is operating the
arm command, the system will arm after the exit delay time is up.)
The output is reset:
1. When the system is disarmed
2. When the output programmed duration is up.
If this duration is programmed as 000, the output will continue till the system disarmed.
3 - System Alarm
This output operates when an alarm occurs.
The output is reset:
1. When the system is disarmed and alarm is reset.
2. When the output programmed duration is up.
When a new alarm occurred, the alarm will reset the alarm time.
If this duration is programmed as 000, the output will continue till the zone restore or system
disarmed.
4 - System Alarm (audile and silent)
In case of audio alarm of the system, the output will be enabled.
Zone (alarm or tamper) programmed to disable zone silent alarm.
System tamper / DX2010 tamper/keypad tamper.
Keypad alarm (emergency alarm, fire alarm, medical aid alarm)
Or in case of silent alarm of the system, the output will be enabled.
Zone (alarm or tamper) programmed to enable zone silent alarm. In case of following
conditions, the output will be reset.
Alarm reset.
Arming of the system.
Disarming of the system.
In case of new alarm event, the output time will be reset and re-timed.
When the output time is set to 000 and the alarm siren sounds for 0, the output will continue
until reset of alarm output or disarming of the system by the command of [PIN] [3] [2] [#].
The output of the following system alarm is only 1 second:
Alarm siren test.
Pacing (tamper/alarm/reset).
Key switch arming or- locking key switch disarming.
5 - External AWAY Siren
The output is triggered when:
System is AWAY armed +zone intruder alarm (intruder alarm = instant / interior instant /
delay / interior delay / delay exit / interior delay exit / follower / interior follower / 24h (can be
silenced) / Fire (can be silenced) / Technical Alarm (can be silenced))
System is AWAY armed +tamper alarm
(no alarm when panel is disarmed)
6 - External STAY Siren
The output is triggered when:
AMAX panel 4000 / AMAX panel 4000
EN
Settings | en 59