LED/LCD Keypad Programming
1. Enable LED keypad or Icon LCD keypad and make sure that the system is in disarmed
status.
2. Enter programming mode: Enter the Installer Code (the default is 1234) + [958] and
press [#].
3. Programming: Move to the required address and enter the value for each data bit (data
value).
– After entering programming mode, the system directly enters the programming data
in the address 0000 (Receiver 1 telephone number or the initial digit of the IP
address), then
– Enter the next address: Press [#]
– Back to the previous address: Press [*]
– Skip to other address: Enter the address code and press [#]
– Set new data in the address: Enter new data values and press [*]
– Enter new data values as required. Otherwise, the factory Default will be used in the
system.
4. Exit programming mode: Enter Command [9] [6] [0] and press [#] to save programming
data. Entering [9] [5] [9] + [#] means not to save the programming data.
For LED/Icon LCD keypad, the programming data is displayed by the keypad indicator. See
Programming Data Indicators.
Notice!
For LED/Icon LCD keypad, when the programming data exceeds the display range of the
keypad indicator, there will be no display on the keypad.
Programming Data Indicators
Data Zone Indicators
Value 1 2 3 4 5 6 7 8 Mains
0
1 X
2 X
3 X
4 X
5 X
6 X
7 X
8 X
9 X X
10 X
11 X X
12 X X
13 X X
8.5.2
90 en | Configuration
AMAX panel 4000 / AMAX panel 4000
EN
2013.07 | 03 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH