3. When the fault is reset, send the restored report to the configured destinations. The FAULT
indicator is turned off when there is no other system fault.
RF Config Failure
Configuration Conflict Sensors
Condition:
Any one wireless zone configuration is error.
Restore:
All wireless zone configuration are correct and fault is reset.
Supervise:
1. Slow flash FAULT indicator (refer to the detailed description in chapter keypad indicators)
2. When the fault is reset, the FAULT indicator is turned off when there is no other system
fault.
Configuration Conflict Repeaters
Condition:
Any one repeater configuration is error.
Restore:
All repeater configuration are correct and fault is reset.
Supervise:
1. Slow flash FAULT indicator (refer to the detailed description in chapter keypad indicators)
2. When the fault is reset, the FAULT indicator is turned off when there is no other system
fault.
Configuration Conflict Keyfobs
Condition:
Any one keyfob configuration is error.
Restore:
All keyfob configuration are correct and fault is reset.
Supervise:
1. Slow flash FAULT indicator (refer to the detailed description in chapter keypad indicators)
2. When the fault is reset, the FAULT indicator is turned off when there is no other system
fault.
2 - Power Failure
The zone indicator 2 lights to indicate Power Faults. Enter [2] to step to Power Faults list for
more information.
Panel AC Failure
Condition:
1. 18V AC supply deficiency to panel caused by transformer.
2. 220V power supply fuse broken.
3. 220V power supply disconnected.
Restore:
AC MAINS supply is reconnected and fault is reset.
1. Monitor the voltage by MPU.
2. If the AC fault is not restored in 1 hour after the fault occurred, report the fault to
configured destination on address 124.
3. Slow flash FAULT indicator (refer to the detailed description in chapter keypad indicators)
4. As the AC supply is reconnected, the MAINS indicator is back to light (except in
Programming Mode or Code Functions Mode ).