If this option is selected, any user allocated to both areas can arm or disarm both areas at the
same time without entering the code at each area codepad.
If the user arms both areas at the same time and Option 1 is selected in Location 500, only an
Arm Report for Area 2 is sent.
If the user disarms both areas at the same time and Option 1 is selected in Location 500, only
a Disarm Report for Area 1 is sent.
Zone allocations
You can allocate up to 16 zones to each zone for the ICP-SOL3_P control panel. The 16
locations for each area are represented by the zone indicators on the ICON codepad. You can
assign any zone to either area or both Area 1 and Area 2 to become a common zone.
Zone, user code, and codepad should be assigned to the correct area to operate. If a user
code is assigned to an area only, the user code can only operate the assigned area on this
area’s codepad. For user code and authority level, Refer to Location 185-189 (for example).
Zones programmed as common zones report to the base station receiver on group zero (Area
1 – Group 1 and Area 2 – Group 2). Zones allocated to only one area report on the
corresponding group number. Common zones, other than 24-Hour zone types, do not activate
an alarm until both areas are armed in either AWAY Mode or STAY Mode 1.
Zone area assignments
Item Location Default New Item Location Default New
Zone 1 area 0502 1 Zone 9 area 0510 1
Zone 2 area 0503 1 Zone 10 area 0511 1
Zone 3 area 0504 1 Zone 11 area 0512 1
Zone 4 area 0505 1 Zone 12 area 0513 1
Zone 5 area 0506 1 Zone 13 area 0514 1
Zone 6 area 0507 1 Zone 14 area 0515 1
Zone 7 area 0508 1 Zone 15 area 0516 1
Zone 8 area 0509 1 Zone 16 area 0517 1
Option
0 = Zone area not assigned
1 = Zone assigned to Area 1
2 = Zone assigned to Area 2
3 = Zone assigned to both Area 1 and Area 2
Example
Program Location 502 as 3, Location 503-509 as 1 , Location 510-517 as 2, Zones 1-8 are
allocated to Area 1 to appear as zones 1-8. Zones 1, 9-16 are allocated to Area 2 to appear as
zones 1, 9-16. In each area’s codepad, zone’s original No is displayed. In this example, If
Zone16 is activated, in Area 2’s ICON codepad, Zone 16 indicator lights. Programming the
same zone into more than one area specifies that zone as a common zone.