If this option is selected, the system can be armed with the zone unsealed. If this option is not
selected, the system does not allow the User Code holder to arm the system until the zone is
sealed or manually isolated. Refer to Isolating zones, page 56 for more information.
8 – Zone Restore Report
If this option is selected, the zone sends Restore Reports when the zone is restored. If this
option is not selected, the zone does not send Restore Reports when the zone is restored.
If a non-24-Hour zone is not restored when the system is disarmed, the system automatically
sends a Zone Restore Report for that zone. All 24-Hour zones send a Zone Restore Report only
when the zone is restored.
Zone Report Options
By default, a zone reports only to Receiver 1. The table below lists the reporting options for
the zone.
Option Description
0 No report required
1 Receiver 1
2 Receiver 2
4 Receiver 1 and Receiver 2
8 Receiver 2 only when Receiver 1 fails
Keyswitch Zone Options
The table below lists the options available to Keyswitch Zones. If you program a zone as a
keyswitch input (Zone Type 11), program the selected Keyswitch Zone options in the location
normally used for Zone Options 1.
Option Description
0 Latching arm and disarm in AWAY Mode
1 Latching arm in AWAY Mode
2 Latching disarm from AWAY Mode, STAY Mode1, or STAY Mode 2
4 Latching arm and disarm in STAY Mode 1
5 Latching arm in STAY Mode 1
6 Latching disarm from STAY Mode 1 or STAY Mode 2
8 Momentary arm and disarm in AWAY Mode
9 Momentary arm in AWAY Mode
10 Momentary disarm from AWAY Mode, STAY Mode1, or STAY Mode 2
12 Momentary arm and disarm in STAY Mode 1
13 Momentary arm in STAY Mode 1
14 Momentary disarm from STAY Mode 1 or STAY Mode 2
0 – Latching Arm and Disarm in AWAY Mode
The system is armed or disarmed from AWAY Mode when using the latching keyswitch input.
9.3.7
9.3.8
Control Panel Zone Information | en 95
Installation Guide 2014.07 | 00n | F01U298026