This output operates when any zone programmed to be silent activates. The output is reset
when the Siren Run Time expires, an audible alarm is activated, or a valid User Code is
entered.
2,2 Alarm When in STAY Mode
This output operates when an audible alarm zone is activated when the system is armed in
STAY Mode 1 or STAY Mode 2. The output is reset when the system is disarmed. Silent alarm
will not trigger this event.
2,3 Alarm When in AWAY Mode
This output operates when an audible zone alarm is activated when the system is armed in
AWAY Mode. The output is reset when the system is disarmed. Silent alarm will not trigger this
event.
2,4 Mimic System Fault
This output operates when any system fault occurs. The output is reset when all system faults
are restored.
2,5 Fire Alarm Resetting
This output operates when a 24-Hour Fire Zone or codepad fire alarm is activated. The output
is reset when a valid User Code is entered or when Siren Run Time expires.
2,6 Fire Alarm Latching
This output operates when a 24-Hour Fire Zone or codepad fire alarm is activated and is reset
when a valid user code is entered in system disarmed state or before the siren time expires in
system armed state.
2,7 Fire Alarm Verification
This feature operates output one second later when a 24-Hour Fire Zone is activated before
Fire alarming or immediately operate output when a 24-Hour Fire Zone is activated after Fire
alarming and before Fire alarming reset. This output event can operate the output only when
the pulse count of the 24-Hour Fire Zone is no less than 2. The output is reset when this Fire
Zone is restored. If no fire zone is activated, this output event is the same with Output Event
0,7.
If the smoke detector trips, the voltage to the smoke detector is disconnected for 15 sec and
then reapplied. No alarm is registered.
2,8 Remote Control 1
This output operates output when using the master code function or A-Link software or
Smartphone App (RSC) to turn remote output 1 on. The output is reset when using the master
code function or A-Link software or Smartphone App (RSC) to manually turn remote output 1
off or automatically turn remote output 1 off when the ON time expires if output polarity is
from 3 to 6 or from 10 to 13.
2,9 Remote Control 2
This output operates output when using the master code function or A-Link software or
Smartphone App (RSC) to turn remote output 2 on. The output is reset when using the master
code function or A-Link software or Smartphone App (RSC) to manually turn remote output 2
off or automatically turn remote output 2 off when the ON time expires if output polarity is
from 3 to 6 or from 10 to 13.
2,10 Remote Control 3
This output operates output when using the master code function or A-Link software or
Smartphone App (RSC) to turn remote output 3 on. The output is reset when using the master
code function or A-Link software or Smartphone App (RSC) to manually turn remote output 3
off or automatically turn remote output 3 off when the ON time expires if output polarity is
from 3 to 6 or from 10 to 13.
2,11 Radio Control Output 1
Control Panel
Programmable Outputs | en 135
Installation Guide 2014.07 | 00n | F01U298026