Reports
Zone Tamper Report
A Zone Tamper Report (Contact ID Event Code144) is sent when Option 14 is programmed in
Location 266 and the zone loop using split EOL resistors (3K3/6K8) with tamper (1K)
becomes open circuit.
Walk Test Report
A Walk Test Report (Contact ID Event Code 607) is sent when either the Installer or Master
Code holder activates Walk Test Mode.
Bypass Report
A zone is bypassed when it is manually isolated. A Zone Bypass Report (Contact ID Event Code
573) is sent at the end of Exit Time for any zone that was manually isolated. A 24-Hour Zone
sends a Zone Bypass Report when the zone is selected to be isolated.
A Zone Bypass Restore Report is sent when the system is disarmed. All bypassed zones are
automatically cleared when the system is disarmed.
The Bypass code parameter has no effect on Contact ID Format because a Zone Bypass is
always reported as Event Code 573.
Notice!
A 24-Hour Fire Zone that is manually bypassed reports as Contact ID Event Code 571.
Other 24-Hour Zone that is manually bypassed reports as Contact ID Event Code 572.
Trouble Report
A zone is in trouble when it is unsealed at the end of Exit Time. A Sensor Trouble Report
(Contact ID Event Code 380) is sent to indicate that one or more zones were automatically
isolated by the system. 24- Hour Zones that are unsealed at the end of Exit Time do not
transmit a Sensor Trouble Report because the restoral for that zone is still outstanding.
A Sensor Trouble Restore Report is sent for Burglary Zones when the zone is resealed or the
next time the system is disarmed (whichever happens first). A 24- Hour Zone sends a restore
signal only when it is resealed.
The Trouble code parameter has no effect on Contact ID Format because a Sensor Trouble
Report is always reported as Event Code 380.
Sensor Watch Report
A Self Test Failure Report (Contact ID Event Code307) is sent to the base station receiver
when a zone was not activated during the Sensor Watch Time programmed in Locations 476
and 477 This report continues to be sent (according to the frequency of the Sensor Watch
Time) until the fault is corrected.
To clear the fault and stop any additional reporting, you must unseal and reseal the zone that
registered the fault. Use the Sensor Watch Time in Locations476 and 477 to set the number of
days a zone can remain sealed without registering a fault.