Swinger Shutdown Count for Siren
Location 379
Default 3
1 to 15 Number of times siren operates until lockout
Location 379 determines the number of times the sirens can be activated before lockout
options take effect. This location has no effect unless you program at least one zone for
lockout siren. Refer to Zone Options 1, page 93 for more information.
Only alarms activated from zone inputs can increment the Swinger Shutdown Counter. Alarms
such as Codepad Panic, Access Denied, and other system alarms do not affect the Swinger
Shutdown Count.
Lockout Siren is separate for each zone, If a zone's siren is locked out, another zone's siren
can still be activated.
Example
Zone1 and 2 are programmed for Lockout Siren with a Swinger Shutdown Count of 2. If Zone
1 activates an alarm, the Swinger Shutdown Count is incremented by one after the end of
Siren Run Time from 0 to a swinger shutdown count of 1.
After the Siren Run Time is reset from the previous alarm, Zone 2 activates an alarm and
activates the sirens. After the sirens are reset, the swinger shutdown count is incremented
again to 1 and the swinger shutdown count for Zone1 is still 1.
If Zone 1 activates an alarm again after the sirens are reset from Zone 2, the Swinger
Shutdown Count is incremented to 2, which locks out Zone 1 only from sounding the sirens
until the system is reset, armed or disarmed.
At this point, Zone 1’s Swinger Shutdown Count for Sirens is reset to 0.
Swinger Shutdown Count for Report
Location 380
Default 6
1 to 15 Number of times the report operates until lockout
Location 380 determines the number of times the report can be activated before lockout
options take effect. This location has no effect unless you program at least one zone for
lockout report. Refer to Zone Options 1, page 93 for more information.
Only alarms activated from zone inputs can decrement the Swinger Shutdown Counter. Alarms
such as Codepad Panic, Code Retries, and other system alarms do not affect the Swinger
Shutdown Count.
Lockout Report is separate for each zone. If a zone's report is locked out, another zone's
report can still be activated. Each zone has a standalone Swinger Shutdown Count for Report.
This counter increases by 1 when a zone activates a system sound alarm from no sound alarm
state.
Use Location 492 to set smart lockout. When a zone report is locked out, if smart lockout is
enabled, lockout events on this zone are not reported if no alarm is sounding. If an alarm is
ongoing, events are reported as configured.