Communicator Information
This section outlines the programming information required for the control panel when
communicating with a base station receiver. These parameters specify the telephone numbers
to call, transmission formats, and transmission speeds.
The control panel can report event information from two on-board communicators. The first
communicator reports to Receiver 1 and the second communicator reports to Receiver 2. You
can program each communicator with two separate telephone numbers, reporting format
type, and Subscriber ID Number.
Example
You can set up Communicator 1 to report in Domestic Dialing Format to Receiver 1 and set up
Communicator 2 to report to a base station receiver in Contact ID Format only if Module 1 is
unsuccessful.
To program a telephone number:
When programming a telephone number, you must program a 0 as a 0 or 10. Each location in
the primary, secondary, and callback telephone numbers stores one digit of the telephone
number.
You must insert a terminator (15) at the end of a telephone number to indicate to the module
the end of the telephone number is reached. The dialing sequence terminates when a 15
appears.
Example
To program the telephone number 9672 1055 as the Primary Telephone Number for Receiver
1, program the following sequence into Locations 000 to 015: [9 6 7 2 1 0 5 5 15 15 15 15 15
15 15 15]
To enter a 4-sec pause in the dialing sequence, program a 13. A pause might be necessary
when the module communicates through an old (slower) telephone exchange or when a PABX
system is in place.
Example
To program the number 02 pause 9 672 1055, enter: [0 2 13 9 6 7 2 1 0 5 5 15 15 15 15 15].
How to program the numbers, keys, and functions for a telephone number, refer to below
table.
Digit Required
Number to Program Digit Required Number to Program
0 0 8 8
1 1 9 9
2 2 10 0
3 3 * * 1
4 4 # * 2
5 5 4-sec Pause * 3
6 6
7 7 Terminator * 5
Table 13.1: Dialing Digits
13
114 en | Communicator Information Control Panel
2014.07 | 00n | F01U298026 Installation Guide