A Chime Zone is not a burglary zone. It can never sound the sirens or activate the
communication module. Its purpose is to map the zone to a programmable output to indicate
if the zone is sealed or unsealed.
Chime zones require EOL resistors and are registered at a remote codepad. These zones do
not affect the operation of forced arming.
15 –Zone Not Used
If a zone is not used, program the zone type location to 15. An EOL resistor is not required if
this zone type is used. This zone type never sounds the sirens or activates the communication
module.
Zone Pulse Count
Zone pulse count is the number of times a zone must be activated before the zone registers an
alarm. The number can vary from 0 to 15. The zone pulse count value is relative to the time
frame (that is, the number of pulses that must be present during a particular time frame).
Zone Pulse Count = 0, means the Zone Pulse Count function is disabled. Refer to Zone Pulse
Count Time, page 92 for more information.
Notice!
A zone that is programmed with a pulse count activates an alarm when it is continuously
unsealed for 10 sec. A 24- Hour Fire Zone programmed with a pulse count activates an alarm
when it is continuously unsealed for 30 sec.
Zone Pulse Count Handover
Zone pulse count handover operates only with Zone Pulse Count Time options 8 to 15.
Any zone that registers one active pulse automatically increments any other zone pulse count
that already registered at least one activate pulse during its respective time. To enable this
feature, select Option 4 in Location 494 (refer to System Options 3, page 107.
Notice!
24-Hour Zones will not receive all handover pulses from other zones. 24-Hour Zones can
handover pulses to other zones.
Zone Pulse Count Time
Zone pulse count time is the time frame or period over which the programmed number of
pulses must register to activate an alarm.
Zone Pulse Count Times
20 ms Option Loop Response Time
(sec)
150 ms Option Loop Response Time
(sec)
0 0.5 8 20
1 1 9 30
2 2 10 40
3 3 11 50
4 4 12 60
5 5 13 90
9.3.3
9.3.4
92 en | Zone Information Control Panel