Bosch TOURING 7500 SERIES Manual del operador Pagina 106

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 260
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 105
Notice!
For all encoders, live view settings are also used for pre-event recording.
For encoders that support dual-streaming, the settings for live/pre-event recording, motion
recording, and alarm recording are all configured independently.
For encoders that support only a single stream (e.g., the VideoJet 8004), live viewing and
recording use the same stream. In this case, the recording settings take priority, so the live
view uses the stream quality settings for continuous, motion, and alarm recording. You can
enter a setting for live/pre-event only if continuous recording is disabled.
You can switch the live stream from stream 2 (default) to stream 1 for a workstation
(Devices > Expand
> > Settings tab > Override recording settings) or for an
encoder. This setting does not affect pre-event recording.
To configure recording settings:
1. In the column of Continuous Recording, select the desired stream quality or disable
continuous recording.
2. In the column, select a check box to activate audio.
3. In the
column of Live/Pre-event Recording, select the desired stream quality or
select stream 1.
4. In the
column, select a check box to activate audio.
5. In the
column of Motion Recording, select the desired stream quality or disable
motion recording.
6. In the column, select a check box to activate audio.
7. In the Pre-event [s] column, click a cell and type the appropriate time.
8. In the Post-event [s] column, click a cell and type the appropriate time.
9. In the column of Alarm Recording, select the desired stream quality or disable alarm
recording.
10. In the column, select a check box to activate audio.
11. In the Pre-event [s] column, click a cell and type the appropriate time.
12. In the Post-event [s] column, click a cell and type the appropriate time.
Notice!
If pre-event time for motion recording and pre-event time for alarm recording differ, the
higher value is used for both.
If the configured pre-event time would overlap a preceding alarm or motion recording, the
pre-event recording starts after the preceding recording is finished.
For detailed information on the various fields, see the Online Help for the appropriate
application window.
106 en | Configuring cameras and recording settings Bosch Video Management System
2013.07 | V1 | Configuration Client Configuration Manual Bosch Sicherheitssysteme GmbH