Alarms page
Main window >
Alarms
Displays the Event Tree and an Alarm Configuration Table for each event. Only the events
configured on the Events page are displayed.
In the tables you configure for each event how an alarm triggered by this event is displayed
and which cameras are recorded and displayed when this alarm occurs.
Some events are configured as alarms per default, e.g., a system error.
For the following events you cannot configure an alarm:
Change of a recording mode
Change of an alarm state
Most of the user actions, e.g. PTZ action
Click to display the Resource Manager dialog box.
Displays a dialog box to set alarm settings valid for this Management Server.
Type in a string and press the ENTER key to filter the
displayed items. Only items containing the string and their corresponding parent items (only
in trees) are displayed. The count of filtered items and the total count of items is provided. An
active filter is indicated by
. Enclose strings with double quotes to find them exactly, for
example "Camera 1" exactly filters the cameras with this name, not camera 201.
To cancel filtering, click .
4 Click a tree item to display the corresponding Alarm Configuration Table.
Device
Displays the device of the event condition selected in the Events Tree.
Network Address
Displays the IP address of the corresponding IP device.
Alarm Identity
In the Priority column, click in a cell to type the alarm priority for the selected alarm (100 is
low priority, 1 is high priority). In the Title column, click in a cell to type the title of the alarm
to be displayed in Bosch VMS, for example in the Alarm List. In the Color column, click in a
cell to display a dialog box for selecting a color for the alarm to be displayed in the
Operator Client, for example in the Alarm List.
Alarm Image Panes
In one of the 1-5 columns, click ... in a cell to display a dialog box for selecting a camera.
You can only select a camera that was added to the Logical Tree in Maps and Structure.
You can configure the number of available Alarm Image panes in the Alarm Settings dialog
box.
In the Audio File column, click ... in a cell to display a dialog box for selecting an audio file
that is played in case of an alarm.
Alarm Options
Click ... in a cell to display the Alarm Options dialog box.