Bosch TOURING 7500 SERIES Manual del operador Pagina 227

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 260
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 226
Entries in this list are only available for a PTZ camera.
Predefined Position
Click a cell to select a predefined position to be set in case of an alarm.
Entries in this list are only available for a PTZ camera.
Notifications tab
E-mail
Select the check box to send an e-mail in case of an alarm.
Server:
Select an e-mail server.
Recipients:
Type the e-mail addresses of the recipients separated by commas (example:
SMS
Select the check box to send an SMS in case of an alarm.
Device:
Select an SMS device.
Recipients:
Type the mobile numbers of the recipients.
Text:
Type the text of the notification.
Information:
Select the check box to add the corresponding information to the notification text.
Note: For an e-mail the date of the time zone of the Management Server is used.
Workflow tab
Record only alarm
Select the check box to specify that the camera is only recorded and not being displayed in
case of this alarm. This check box is only active if the Record check box on the Cameras tab is
selected.
Auto-clear alarm after configured time ('Alarm Settings' dialog box)
Select the check box to specify that this alarm is automatically cleared.
Auto-clear alarm when event state changes back to normal
Select the check box to specify that this alarm is automatically cleared when the event that
triggers this alarm changes its state. The alarm will not be cleared automatically if it is
accepted and unaccepted.
Show action plan
Select the check box to enable the workflow that must be processed in case of an alarm.
Resources...
Click to display the Resource Manager dialog box. Select a document with a description of
the corresponding workflow.
Display a comment box
Select the check box to enable displaying a comment box in case of an alarm. In this comment
box the user can type comments on the alarm.
Force the operator to process the workflow
Select the check box to force the user to process the workflow. If selected, the user cannot
clear the alarm until he has entered a comment on the alarm.
Execute the following Client Script when alarm is accepted:
Select a Client Command Script that is executed automatically, when the user accepts an
alarm.
Bosch Video Management System
Alarms page | en 227
Bosch Sicherheitssysteme GmbH Configuration Manual 2013.07 | V1 | Configuration Client
Vista de pagina 226
1 2 ... 222 223 224 225 226 227 228 229 230 231 232 ... 259 260

Comentarios a estos manuales