Vista de pagina 189
Tamper detection
See Tamper detection, page 191
Load...
Click to load a saved profile. The the Open dialog box is displayed. Select the filename of the
profile you want to load, and then click OK.
Save...
Click to save the profile settings to another file. The Save dialog box is displayed. Type the
filename, select the folder where to save the file, and then click OK.
Default
Click to return all settings to their default values.
Motion detector (MOTION+ only)
Reflections of light (from glass surfaces, etc.), lights switching on and off, or changes in the
light level caused by cloud movement on a sunny day can trigger unintended responses from
the motion detector and generate false alarms. For indoor surveillance, ensure constant
lighting of the areas during the day and at night. Run a series of tests at different times of the
day and night to ensure that the video sensor is operating as intended.
Debounce time 1s (MOTION+ only)
The debounce time is intended to prevent very brief events from triggering individual alarms. If
the Debounce time 1s option is activated, an event must last at least 1 second to trigger an
alarm.
Select Area...
Click to configure the areas to be monitored by the motion detector. The Select Area dialog
box is displayed.
See Select Area dialog box, page 190.
Sensitivity (only with MOTION+ functionality)
Move the slider to adjust the sensitivity of the motion detector. The motion detector reacts to
variations in the brightness of the video image. The darker the observation area, the higher the
value that must be selected.
Minimum object size (only with MOTION+ functionality)
Specify the number of sensor fields that a moving object must cover to generate an alarm.
This settings prevents small objects from triggering an alarm.
A minimum value of 4 is recommended. This value corresponds to four sensor fields.
Select Area dialog box
This dialog box displays the camera image. Within this window you can activate the areas of
the image to be monitored.
To activate an area:
In the camera image, drag over the area you want to activate. Activated areas are marked
yellow.
To deactivate an area:
In the camera image, press the SHIFT key and click the area you want to deactivate.
To obtain commands in the window:
To see the commands for activating or deactivating the areas, right-click anywhere in the
window. The following commands are available:
Undo
Undoes the last command.
Set All
Activates the entire camera image.
Clear All