In the router that connects your private network with the public network, you configure the
same port mapping. The router then forwards each packet with public port number from the
public network to the private IP address and port number. Private IP address and port number
have been configured in the port mapping table for this public port number.
Notice!
Additionally in the router you must manually configure the port forwarding according to the
settings in the port mapping table.
Enable Port Mapping
Click to enable / disable port mapping.
Add
Click to add a port range in the Port ranges list.
Edit
Click to change a selected entry in the Port ranges list.
Remove
Click to remove a selected entry in the Port ranges list.
Private IP address (for access within the LAN)
Select the private IP address of your Management Server local network adapter.
Public network address (for access from external, e.g. via Internet)
Type in the public network address of this private network. The remote Operator Client logs
on with this public network address to get access to the devices of this Management Server.
Show Port Fowarding...
Click to display the Port Mapping Table dialog box.
Related Topics
– Remote access, page 25
Show Port Mapping dialog box
Main window > Settings menu > Remote Access Settings... command > Show Port
Fowarding... button
Displays the port mapping for the IP addresses of the configured devices in your Bosch VMS.
Private IP
Displays the private network address of each configured device.
Private Port
Displays the private port number used in the private network for this device.
Allows you to change the value manually.
Public Port
Displays the public port number used by Operator Client from public networks to access this
device.
Allows you to change the value manually.
Fixed
Click to check to fix the manually assigned port number.
Click to uncheck to enable the automatic assignment of a port number.
Copy to Clipboard
Click to copy the mapping table to the clipboard. This helps you in creating a configuration
script for a port mapping in a router (for example a RRAS service).