VRM Devices page
Main window > Devices > Expand >
Allows you to add and configure VRM devices. A VRM device needs at least an encoder, an
iSCSI device, and a LUN assigned to the iSCSI device, and a storage pool. See the Release
Notes and the data sheet for current firmware versions.
Caution!
After you have added an iSCSI device with respective encoders to your Bosch VMS, you must
add the IQN of each encoder to this iSCSI device (valid for some iSCSI device types).
See Configuring an iSCSI device, page 64 for details.
Caution!
Ensure that the time of the VRM computer is synchronized with the Management Server.
Otherwise you can loose recordings.
Configure the time server software on the Management Server. On the VRM computer,
configure the IP address of the Management Server as time server using standard Windows
procedures.
VRM Settings page
Main window > Devices > Expand > >
VRM Server name
Type a name that is displayed in the device tree of Bosch Video Client.
Server initiator name
Displays the iSCSI initiator name of VRM Server.
System-wide CHAP password
Enter the password that you have configured in the iSCSI storage device. The CHAP password
is valid for the VRM and is sent to all devices automatically. Replay clients do not need
additional configuration. You must configure the iSCSI systems manually with the CHAP
password. If you are using a CHAP password, all storage systems have to be configured to use
the CHAP password. Only one system wide CHAP password is supported by the VRM system.
Use as failover server / Master server IP address / Password
You can set up a computer as the master server, provided that VRM Server is started on it, and
set up another computer as a failover server. The configuration settings of the master server
are then synchronized on the failover server. If the master server fails, the failover server
automatically takes over the management of the VRM system.
Check Now
Click to reassign the devices of all storage pools to their iSCSI storage systems. This is only
being performed on storage pools with Automatic recording mode.
23.25
23.26
Bosch Video Management System Devices page | en 169