Periphery page
COM1
This function allows you to configure the serial interface parameters according to your
requirements.
If the device is working in multicast mode, the first remote location to establish a video
connection to the device is also assigned the transparent data connection. However, after
about 15 seconds of inactivity the data connection is automatically terminated and another
remote location can exchange transparent data with the device.
Serial port function
Select a controllable device from the list. Select Transparent data to transmit transparent data
via the serial port. Select Terminal to operate the device from a terminal.
After selecting a device, the remaining parameters in the window are set automatically and
should not be changed.
Baud rate (bps)
Select the value for the transmission rate.
Stop bits
Select the number of stop bits per character.
Parity check
Select the type of parity check.
Interface mode
Select the protocol for the serial interface.
Network Access page
The settings on this page are used to integrate the device into an existing network.
Note:
After changing the Subnet mask and/or the Gateway address, restart the computer.
Automatic IP assignment
Notice!
If a DHCP server is employed in the network for the dynamic assignment of IP addresses,
activate acceptance of IP addresses automatically assigned to the device.
Certain applications (VRM, Bosch Video Management System, Bosch Video
Client,Configuration Manager) use the IP address for the unique assignment of the device. If
using these applications, the DHCP server must support the fixed assignment between IP
address and MAC address, and must be appropriately set up so that, once an IP address is
assigned, it is retained each time the system is rebooted.
Subnet mask:
Type the subnet mask number of the device obtained from your network administrator.
Gateway address
Type the IP address for the gateway to connect the device to a remote location in a different
subnet. Otherwise, this box can remain empty (0.0.0.0).
Prefix length
Enter the appropriate prefix length for the set IP address.
Gateway address
For the device to establish a connection to a remote location in a different subnet, enter the IP
address of the gateway here. Otherwise, this field can remain empty (0.0.0.0).