Page 12 P/N: 49211C © 2002 Detection Systems, Inc. All rights reserved. DS7240/DS7220 User's Guide
PART II: KEYPAD USER’S GUIDE: DS7447i LCD KEYPAD
The keypad display shows the following for
turning the system All On:
120 seconds to
All On.
To bypass zones
Press Bypass.
For no entry
Press No Entry.
The display shows the following for Perimeter
Only (display shows “Partial On” if the system is
turned Partial On):
120 seconds to
Perimeter On.
To bypass zones
Press Bypass.
For no entry
Press No Entry.
4. To turn the system on (All On, Perimeter Only or
Partial On) with no entry delay, press the [No
Entry] key. See page 11 for more information.
4.10 Force Arming the System
Force-arming is not permitted for UL
applications.
I can perform this function.
I cannot perform this function.
4.10.1 Force Arming with Normal Exit Delay and Exit
Tone
Procedure
1. Enter a valid user PIN.
2. Turn the system on using one of the following
methods:
All On: Press [On] (or enter [#] +[1])
Perimeter Only: Press [Perimeter Only] (or
enter [#] + [2])
Partial On: Enter [#] + [3]
If a zone is faulted, the keypad displays the
following:
Zn 5 faulted,
Zone Text
To Bypass Zn 5
Press 5 + *
3. Re-enter the sequence from Step 2 that you used
to turn the system on (for example, if you press
[On] in Step 2, press [On] again). The following
message scrolls across the display:
Forced on!
60 seconds to
All On.
1 zones are
forced on.
The display above uses an Exit Delay time of 60
seconds and only one zone is force armed.
Exit Delay time and the number of zones force-
armed may vary.
4.10.2 Force Arming with Doubled Exit Delay and No Exit
Tone
1. Enter a valid user PIN.
2. Turn the system on using one of the following
methods:
Arming Function To Silence Exit Tone
Press and hold [On]
OR
All On
Press [#], then press and hold the [1] key
Press and hold [Perimeter Only]
OR
Perimeter Only
Press [#], then press and hold the [2] key
Partial On Press [#], then press and hold the [3] key
Table 7: No Exit Tone Key Sequences
3. When the “Zn Faulted” message appears (see
display under Step 2 of previous section), re-
enter the arming sequence used in Step 2 of this
section.
For example, if you turned the system on by
pressing and holding the [On] key, press the [On]
key again. Do not press and hold the key.
The “Forced On!” message appears and the
doubled Exit Delay countdown begins. The
keypad does not emit an Exit Tone.
The system forces the faulted zones on. As long as
they remain faulted they do not provide coverage. If
they return to normal before the system is turned off,
they provide coverage and are capable of starting
alarm events. If a zone becomes faulted after Exit
Delay begins, the keypad displays the faulted zone. If
the zone remains faulted at the end of Exit Delay, it
starts an alarm event.