Page 48 P/N: 49211C © 2002 Detection Systems, Inc. All rights reserved. DS7240/DS7220 User's Guide
PART III: REFERENCE MATERIALS
Event
#
Event Description Event
#
Event Description
41
ChckSum Fail,
Dbus
Checksum on Data Bus device
parameters failed. Contact Security
Company.
61 Frc, All, -Dly, Usr
System forced All On with no delay (instant)
by user.
42 Cls, All, +Dly, Skd System turned All On with Entry
Delay by Sked.
62 Frc, Prt, +Dly, Skd System forced Perimeter On with Entry Delay
by Sked.
43 Cls, All, +Dly, KS
System turned All On with Entry
Delay by keyswitch.
63 Frc, Prt, +Dly, KS
System forced Perimeter On with Entry Delay
by keyswitch.
44 Cls, All, +Dly,
RPS
System turned All On with Entry
Delay by DS-RPS.
64 Frc, Prt, +Dly, RPS System forced Perimeter On with Entry Delay
by DS-RPS.
45 Cls, All, +Dly, Tel System turned All On with Entry
Delay by telephone.
65 Frc, Prt, +Dly, Usr System forced Perimeter On with Entry Delay
by user.
46 Cls, All, +Dly, Usr System turned All On with Entry
Delay by user.
66 Frc, Prt, -Dly, RPS System forced Perimeter On with no delay
(instant) by DS-RPS.
47 Cls, All, -Dly, RPS System turned All On with no delay
(instant) by DS-RPS.
67 Frc, Prt, -Dly, Usr System forced Perimeter On with no delay
(instant) by user.
48 Cls, All, -Dly, Usr
System turned All On with no delay
(instant) by user.
68 Reserved.
49 Cls, Prt, +Dly, Skd System turned Perimeter On with
Entry Delay by Sked.
69 CommFail Report failed to reach routing destination.
50 Cls, Prt, +Dly, KS
System turned Perimeter On with
Entry Delay by keyswitch.
70
Comm Fail,
AltComm
Report failed to reach routing destination
configured for Alternate Communication.
51 Cls, Prt, +Dly,
RPS
System turned Perimeter On with
Entry Delay by DS-RPS.
71 Comm Restoral After communication fail, report sent
successfully to routing destination.
52 Cls, Prt, +Dly, Usr System turned Perimeter On with
Entry Delay by user.
72 Comm Rstl,
AltComm
After communication fail, report sent
successfully to routing destination configured
for Alternate Communication.
53 Cls, Prt, -Dly,
RPS
System turned Perimeter On with
no delay (instant) by DS-RPS.
73 Date/Time Change Date/Time in panel changed.
54 Cls, Prt, -Dly, Usr
System turned Perimeter On with
no delay (instant) by user.
74 Duress
User entered Duress PIN or pressed Panic
key sequence on RF keyfob.
55 Frc, All, +Dly, Skd System forced All On with Entry
Delay by Sked.
75 Fire, Alarm Alarm event on fire detection device(s).
56 Frc, All, +Dly, KS System forced All On with Entry
Delay by keyswitch.
76 Fire, Cross Verified alarm event on fire detection
device(s) with Cross Zone option.
57
Frc, All, +Dly,
RPS
System forced All On with Entry
Delay by DS-RPS.
77 Fire, Unverified
Unverified alarm event on fire detection
device(s) with Cross Zone option.
58 Frc, All, +Dly, Tel System forced All On with Entry
Delay by telephone.
78 Fire, Missing Fire detection device(s) assigned to zone
expander (wired or RF) not responding to
panel’s status poll.
59 Frc, All, +Dly, Usr System forced All On with Entry
Delay by user.
79 Fire, Alrm, Rstl Restoral from alarm, fire detection device(s).
60 Frc, All, -Dly, RPS System forced All On with no delay
(instant) by DS-RPS.
80 Fire, Trouble Trouble condition on fire detection device(s).
Table 18 (cont.): Panel Event Descriptions