Page 32 P/N: 49211C © 2002 Detection Systems, Inc. All rights reserved. DS7240/DS7220 User's Guide
PART II: KEYPAD USER’S GUIDE: DS7445i LED KEYPAD
5.6 Turn the System Partial On
I can perform this function.
I cannot perform this function.
Exit Delay Time (to be filled in by your Security
Company):
You have __________ seconds to exit the premises.
Key Sequence: [#] + [3]
Description
Partial On turns on part of your system designated as
Partial On, leaving the rest of the system turned off.
You can select the zones that turn on for Partial On
(see page “Set Partial On Zones”).
Procedure
1. Make sure that Partial On zones are normal (not
faulted). If your system has a faulted zone, you
should return it to normal, or bypass it (see
“Bypass Zones” on page 35).
2. Enter a valid user PIN.
3. Press [#] + [3] to turn the system Partial On.
4. The Armed and Perimeter LEDs turn on and Exit
Delay time starts.
On
Status
Power
Fire
Supervisory
Bell Silenced
Trouble
TEST WEEKLY
1 2 3 4 5 6 7 8
9 10 11 12
13 14
15 16
Armed and Periemter LEDs ON
Armed Perimeter
During Exit Delay, you may stop the system from
turning on by entering your PIN.
If you wish, you can turn the system Partial On
with No Entry by pressing the [No Entry] key.
During the last 10 seconds of Exit Delay, the
keypad allows for a “last chance” response to
disarm the system. During this time, the keypad
emits a double tone every second. The system
then turns Part On. The Armed and Perimeter
LEDs remain turned on.
5. To turn the system off, enter a valid PIN.
5.7 Set Partial On Zones
I can perform this function.
I cannot perform this function.
Key Sequence: [#] + [6] + [5]
Description
Use this function to select which zones are armed
when you turn the system Partial On. This allows you
to turn part of the system on to detect intrusion, while
the remaining part of the system allows you to move
freely without sounding an alarm.
Procedure
1. Make sure that the system is turned off (Armed
and Perimeter LEDs are off).
2. Enter a valid user PIN.
3. Press [#] + [6] + [5].
4. The keypad indicates which zones are available
for selections. Zone LEDs that are on are already
selected for Partial On, flashing zone LEDs are
available for selection.
On
Status
Power
Fire
Supervisory
Bell Silenced
Trouble
TEST WEEKLY
1 2 3 4 5 6 7 8
9 10 11 12
13 14
15 16
LEDs ON
Armed Perimeter
LEDs Flashing
5. Enter the Zone Number that you want to activate
or deactivate for Partial On followed by the [∗]
key. Repeat this step until the LEDs for all of the
zones you wish to designate for Partial On
operation are on.
6. Press the [#] key to save your selections and exit
this function.