Page 20 P/N: 49211C © 2002 Detection Systems, Inc. All rights reserved. DS7240/DS7220 User's Guide
PART II: KEYPAD USER’S GUIDE: DS7447i LCD KEYPAD
The strobe output is tested next. This test resets
after approximately 20 minutes, or when the [*]
key is pressed.
Testing Strobe.
Press * to end.
Check for strobe activation.
The backup battery is tested next. This test may
take up to 4 minutes.
Testing battery.
May take 4 min.
The keypad displays the results of the battery
test:
Battery Test
Passed.
OR
Battery Test
Failed!
Please call for
Service.
Finally, the phone connection is tested. This test
may take up to 10 minutes:
Testing Phone.
May take 10 min.
The keypad displays the results of the phone line
test:
Phone Test
Passed.
OR
Phone Test
Failed!
Please check for
dial tone.
4. When the test is complete, the system returns to
the normal display.
To stop the test currently in progress and skip to
the next test, press the [*] key. To abort all
system tests and return to the normal display,
press the [#] key.
4.25 Walk Test
I can perform this function.
I cannot perform this function.
Key Sequence: [#] + [4] + [4]
Description
Use this function to walk-test detection devices
connected to your system. Perform the Walk Test
on a weekly basis.
Your Security Company configures the types of
devices that can be walk-tested.
Procedure
1. Make sure that the system is turned off (Armed
LED is off).
2. Enter a valid user PIN.
3. Enter [#] + [4] + [4]. The system starts the Walk
Test.
The keypad scrolls all zones that need to be
tested (zones scroll one at a time). To
successfully test each zone, you need to trigger
the corresponding detection device (open a door,
walk in front of a motion detector, etc.).
Zn2 Un-Tested
Front Door
Zn3 Un-Tested
Hallway
Zn4 Un-Tested
Living Room
To stop test
Press #
You may press the [#] key to stop the Walk Test.
Test fire detection devices (smoke/heat
detectors) weekly as instructed by your
Security Company and in accordance with the
devices’ instructions.