PART II: KEYPAD USER’S GUIDE: DS7445i LED KEYPAD
5.0 Using the DS7445i LED Keypad
The DS7445i LED Keypad can only display
Zones 1-16 or Users 1-16. Any functions that
require displaying zones or users higher than
16 cannot be performed from this keypad.
The DS7445i LED Keypad turns an LED (or series of
LEDs) ON or flashes an LED (or series of LEDs) to
indicate system events and conditions by.
= LED ON
= LED Flashing
See Table 4 on page 6 for DS7445i LED functions.
5.1 Silence Alarms
Description
When an alarm occurs, the alarm tone sounds and
the zone(s) in alarm illuminate on the display (up to
Zone 16).
If you enter your PIN before the abort timer
expires, the alarm report is aborted (non-fire
alarms only).
Procedure
1. Enter your PIN to silence an alarm and turn the
system off (if it was turned on). An alarm report is
sent if the alarm is not acknowledged in time.
2. Press and hold the [#] key to remove the alarms
(flashing zone numbers) from the keypad display.
See View Alarm Memory” on page 40 to see
which zones caused the alarm.
5.2 Keypad Adjust
I can perform this function.
I cannot perform this function.
Key Sequence: [#] + [4] + [9]
Description
Use this function to adjust the keypad’s sounder
volume (non-alarm tones).
1. Enter a valid user PIN.
2. Press [#] + [4] + [9].
3. To adjust the keypad’s sounder volume and non-
alarm tone volume, press and hold the [*] key,
and then press [1] to increase the volume or [4]
to decrease the volume.
4. Press the [#] key to save the setting and exit this
function.
5.3 Turn the System Off
Entry Delay Time (to be filled in by your Security
Company):
You have __________ seconds to enter the premises
and turn the system off.
Description
Turn the security system off by entering your PIN.
When the system is on, you must enter through a
designated Entry door to prevent an alarm. Opening a
designated door starts Entry Delay. During Entry
Delay time, the keypad emits a double tone every
second to remind you to turn the system off. Enter
your PIN before the Entry Delay time expires to turn
the system off.
If you enter through the wrong door or fail to turn the
system off before the Entry Delay time expires, you
may cause an alarm. If an alarm occurs, silence the
alarm by entering your PIN and call your Security
Company to let them know that it is not an emergency
situation.
Procedure
1. When the system is All On, the keypad’s Armed
LED is on. If the system is on Perimeter Only or
Partial On, the keypad’s Perimeter LED is on as
well.
On
Status
Power
Fire
Perimeter
Supervisory
Bell Silenced
Trouble
TEST WEEKLY
1 2 3 4 5 6 7 8
9 10
11 12
13 14
15 16
Armed
System is All On
On
Status
Fire
Supervisory
Bell Silenced
Trouble
TEST WEEKLY
1 2 3 4 5 6 7 8
9 10
11 12 13
14 15
16
Armed
System is Perimeter Only on or Partial On
Perimeter
Power
2. Enter your PIN to turn the system off. Once the
system is off, the keypad turns the Armed LED or
Perimeter LED off.