ECODRIVE Drive Controller DKC02.1
DOK-ECODRV-SSE-03VRS**-WAR1-EN-P 12.96 Command Diagnostic Messages 4-11
C227 Modulo range error
See functional description of "Modulo processing boundary conditions"
C300 Set absolute measuring
The command P-0-0012, Command ’Set Absolute Measurement’ has
been activated via the employed controller.
C301 Setting Absolute Measuring Not Allowed, Drive Enable
Cause:
The command "C300 Set absolute measuring emulator" has been
started while the controller enable signal was active.
Remedial action:
Terminate the command and de-activate the controller enable signal.
C302 Absolute Measuring System Not Installed
The command P-0-0012, Command ’Set Absolute Measurement’ has
been started without an absolute measuring system being available.
The command can only be executed if an absolute measuring system
exists.
Cause:
1. The command has incorrectly been activated.
2. The connected motor or the external measuring system are not
designed as absolute encoders.
Remedial action:
Ref. 1. Prevent command execution.
Ref. 2. Equip motor or external measuring system with absolute encoder
functions.