MPH-02, MPB-02, MPD-02 Master Communication 4-67
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
When drive enable is set and the "Drive Halt" signal is active (P-0-4028 or
P-0-0116, bit 13 = 0),
the display of the control panel changes to "AH" and
the diagnostic drive message then is A0010 Drive HALT and thereby
signals the activation of "Drive Halt".
If the "Drive Halt" signal is then deactivated (P-0-4028 or P-0-0116,
bit 13 = 1),
the display of the control panel changes to "AF" and
the diagnostic drive message is dependent on the active mode of
operation (see Troubleshooting Guide).
Note: The "Drive Halt" signal is status-controlled and active when the
signal = 0 V.
A positive edge at the "clear error" input starts the command for error
clearing. To do this, the command C0500 has to be assigned to a digital
input:
configure parameter S-0-0099, C0500 Reset class 1 diagnostics in
P-0-0300, Digital I/Os, assignment list
in parameter P-0-0301, Digital I/Os, bit numbers set bit 0 for the
element of S-0-0099
in parameter P-0-0302, Digital I/Os, direction set the data direction
for the element of S-0-0099 to input (value "0")
See also "Digital Inputs/Outputs" in chapter "Extended Drive Functions"
Note: By activating the command for error clearing all drive errors
are cleared!
Analog Command Value Input
The number of analog inputs, which differs according to control section, is
used to input the analog command value.
For IndraDrive devices the analog inputs are cyclically sampled and
evaluated:
assignment channel A works in position loop clock
(advanced: T = 250µs, basic: T = 500µs)
assignment channel B works in 2ms clock
See also "Analog Inputs" in chapter "Extended Drive Functions"
Emulation of Position Value
In order to close the position control loop via the master, it is necessary to
transmit the axis position to the master. This is done by means of encoder
emulation (incremental or SSI).
See "Encoder Emulation" in chapter "Extended Drive Functions"
"Drive Halt" Signal
Clearing Errors