MPH-02, MPB-02, MPD-02 Handling, Diagnostic and Service Functions 10-35
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Starting from the extended display it is possible to activate commands
and make settings:
set the drive address (drive number in the bus system of the master
communication)
set the length of the fiber optic cable
activate the "analog mode" master communication
C07_x load defaults procedure command (loading controller
parameters resp. base parameters)
other commands like
C2200 Backup working memory procedure command
C2300 Load working memory command
C2500 Copy IDN from optional memory to internal memory
C2600 Copy IDN from internal memory to optional memory
C2900 Firmware update from MMC
Command Inputs