7-102 Operating Modes MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Phase Synchronization with Real/Virtual Master Axis
Brief Description
In the operating mode "phase synchronization with real/virtual master
axis" the drive follows a preset master axis position in an absolute or
relative phase synchronous way.
The real master axis position is generated by a master axis encoder, the
virtual master axis position is preset by the master.
See also "Dynamic Synchronization with Synchronous Position Control
Modes" in section "Basic Functions of the Synchronization Modes"
determination of the position command value from the master axis
position using the electronic gear and fine adjust, adjustable master
axis polarity
adjustable master axis cycle and actual value cycle, displayed
command value cycle
synchronization mode to be selected
standard (trapezoidal)
register controller (PT1 filter)
additive master axis position
absolute and modulo processing of the master axis
absolute or relative phase synchronization
synchronization range to be selected
modulo range
command value cycle
part of command value cycle
additive position command value
There are the following variants of the operating mode to be selected:
phase synchronization with real master axis, encoder 1
phase synchronization with real master axis, encoder 2
phase synchronization with real master axis, encoder 1, lagless
phase synchronization with real master axis, encoder 2, lagless
phase synchronization with virtual master axis, encoder 1
phase synchronization with virtual master axis, encoder 2
phase synchronization with virtual master axis, encoder 1, lagless
phase synchronization with virtual master axis, encoder 2, lagless
Features
Variants of the Operating Mode
Expansion package synchronization (order code SNC) in closed-loop characteristic
Vista de pagina 407