Bosch PIN8 N1 Guía para resolver problemas Pagina 563

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 728
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 562
MPH-02, MPB-02, MPD-02 Extended Drive Functions 9-35
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
See also Parameter Description "P-0-0218, Analog input, control
parameter"
By means of the assignment mechanism (assignment A or B) it is
possible to assign the analog input values to drive parameters.
Assignment takes place in the following parameters:
P-0-0213, Analog input, assignment A, target parameter
P-0-0236, Analog input, assignment B, target parameter
Possibilities of Access via Command Communication
and IndraMotion MLD-S
The analog input values of the max. 4 analog inputs are stored in the
following parameters for display and further internal processing:
P-0-0210, Analog input 1
P-0-0228, Analog input 3
P-0-0229, Analog input 4
Additionally for basic design:
P-0-0211, Analog input 2
It is therefore possible to configure these digitized analog values into the
cyclic telegram of the master communication (cf. S-0-0016 or P-0-4081)
or to access one of the above parameters directly from a PLC program.
Specific Features of Double-Axis Design (MPD02VRS)
Every analog input (1,3 or 4) can be parameterized without restrictions for
both axes of a double axis.
Only the provided input voltage is used in common.
The respective evaluation and interpretation depends on how the
individual axes have been parameterized (cf. assignment A and B).
Note: The parameters P-0-0210 to P-0-0239 are available separately
for each axis. The parameters P-0-3901 and P-0-3904 are
only available once per device!
Diagnostic Messages and Status Displays
As regards the "analog inputs" function, the following diagnostic
command messages can occur:
C2800 Analog input adjust command
C2802 Oscillations of input signal outside tolerance range
C2803 Measured values at zero point and max. value identical
C2804 Automatic adjust failed
See descriptions of diagnostic messages in the separate
documentation "Troubleshooting Guide"
Assignment to Drive Parameters
Vista de pagina 562