Bosch PIN8 N1 Guía para resolver problemas Pagina 304

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 728
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 303
6-92 Drive Control MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
CAUTION
Property damage caused by inadmissibly high
voltage on the motor terminals!
For third-party motors the maximum allowed terminal
voltage has to be observed!
Diagnostic and Status Messages
Displaying module bus status:
P-0-0461, Module group, status word
Displaying device-side module bus control information:
P-0-0460, Module group, control word
Displaying interrupted module bus communication:
F2087 Module group communication error
Mains voltage diagnoses:
P-0-0806, Current mains voltage crest value
P-0-0815, Nominal mains voltage crest value
Mains voltage warnings:
E2814 Undervoltage in mains
E2818 Phase failure
E2819 Mains failure
Mains voltage error messages:
F2814 Undervoltage in mains
F2816 Softstart fault power supply unit
F2818 Phase failure
F2819 Mains failure
F2834 Contactor control error
F2840 Error supply shutdown
F2860 Overcurrent in mains-side power section
DC bus diagnosis:
S-0-0380, DC bus voltage
DC bus warnings:
E2026 Undervoltage in power section
E2026 Undervoltage in power section
E8025 Overvoltage in power section
DC bus error messages:
F2026 Undervoltage in power section
F2817 Overvoltage in power section
F2833 Ground fault in motor line
F2836 DC bus balancing monitor error
Module Bus
Mains Voltage
DC Bus
Vista de pagina 303
1 2 ... 299 300 301 302 303 304 305 306 307 308 309 ... 727 728

Comentarios a estos manuales

Sin comentarios