6-48 Drive Control MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
INBWG (moving)
drive enable
start of automat.
controller setting
diagnostic display
velocity profile
t
t
Ab
AF
AH
AFC1800
duration of autom. controller setting
standstill window
SV5008D2.fh7
start of automatic controller setting via
command C1800 (P-0-0162)
AH/START
v
Fig. 6-31: Signal flow chart for motion by command start
INBWG (moving)
drive enable
t
v
Ab AH
AH
standstill window
SV5010D2.fh7
t
AF
C1800
start of automat.
controller setting
velocity profile
AH/START
diagnostic display
start of automatic controller setting via
command C1800 (P-0-0162)
duration of autom. controller setting
Fig. 6-32: Signal flow chart for motion by "drive start"
Triggering the Motion by
Starting Command C1800
Triggering the Motion by "Drive
Start"