MPH-02, MPB-02, MPD-02 Drive Control 6-43
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
• possible settings in P-0-0165, Selection for autom. controller adjust
for:
• velocity loop
• position loop
• acceleration feedforward
• determination of load inertia
• determination of maximum acceleration
• oscillation movement/unipolar movement
• absolute travel limits/relative movement around the starting position
• P-0-0162, C1800 Command Automatic control loop adjust
• P-0-0163, Damping factor for autom. controller adjust
• P-0-0164, Application for autom. controller adjust
• P-0-0165, Selection for autom. controller adjust
• P-0-0166, Lower limit for autom. control loop adjust
• P-0-0167, Upper limit for autom. control loop adjust
• P-0-0168, Maximum acceleration to be parameterized
• P-0-0169, Travel distance for autom. controller adjust
• C1800 Command automatic control loop setting
• C1801 Start requires drive enable
• C1802 Motor feedback data not valid
• C1803 Inertia detection failed
• C1804 Automatic controller setting failed
• C1805 Travel range invalid
• C1806 Travel range exceeded
• C1807 Determining travel range only via travel distance
• E2047 Interpolation velocity = 0
• E2048 Interpolation acceleration = 0
• E2049 Positioning velocity >= S-0-0091
• E2055 Feedrate override S-0-0108 = 0
• F2039 Maximum acceleration exceeded
Prerequisites for Starting the Automatic Control Loop
Setting
CAUTION
Property damage and/or personal injury caused
by drive motion!
During the execution of command C1800 Command
automatic control loop setting, the drive moves
automatically, i. e. without external command values.
⇒ Check and make sure that the E-Stop circuit and the
travel range limit switches are working.
See also chapter: "Safety Instructions for Electric Drives
and Controls"
Pertinent Parameters
Pertinent Diagnostic Messages