6-24 Drive Control MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
The input value in P-0-0523 required for determining the commutation
offset must be calculated from the measured relative position of primary
part with regard to secondary part (see fig. "Measuring the relative
position between primary and secondary part", distance d, e, f or g,
according to possibility of access), as well as a motor-dependent constant
k
mx
(see "Calculation formulas for P-0-0523" and table "Motor constant
k
mx
for commutation setting").
mxp
mxp
mx
mx
klgmm P :4 point reference
klf P :3 point reference
mm keP :2 point reference
kdP :1 point reference
−−−=−−
−−−=−−
−−=−−
−=−−
5.3705230
05230
5.3705230
05230
P-0-0523: commutation setting measured value in mm
d: distance reference point 1 – front side of primary part in mm
1)
e: distance reference point 2 – front side of primary part in mm
1)
f: distance reference point 3 – front side of primary part in mm
1)
g: distance reference point 4 – front side of primary part in mm
1)
k
mx
: motor constant for commutation setting in mm
l
p
: length of primary part in mm
1)
: see fig. above "Measuring the relative position between primary and
secondary part"
Fig. 6-19: Calculation formulas for P-0-0523
Note: When determining P-0-0523, Commutation setting
measured value you have to make sure the preceding sign is
correct.
If P-0-0523 is determined with a negative sign, this has to be
entered!
Calculating P-0-0523,
Commutation setting measured
value