5-88 Motor, Mechanical Axis System, Measuring Systems MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Diagnostic Messages of Scaling Setting
If inadmissible scaling settings were made, they are detected when
switching from parameter mode (communication phase 2) to operating
mode (communication phase 4). The drive in this case does not reach the
operating mode and, according to setting, displays the following
command errors:
• C0122 Incorr. parameteriz. of motor enc. (mechanical system)
• C0123 Modulo value for motor encoder cannot be displayed
• C0127 Incorr. parameteriz. of opt. enc. (mechanical system)
• C0128 Modulo value for optional encoder cannot be displayed
• C0140 Rotary scaling not allowed
• C0101 Invalid parameters (see S-0-0021)
• C0102 Limit error in parameter (-> S-0-0021)
• C0103 Parameter conversion error (->S-0-0021)
Example of Scaling Settings
There are many possibilities to make settings for the scaling type. The
table below shows useful settings for which there aren’t any command
errors to be expected:
Mechanical system Encoder Useful scaling type settings
Motor Load
gear
Feed
spindle
Motor
encoder
External
encoder
Motor reference Load reference Modulo
available not
available
rotary no rotary rotary possible
rotary --- possibleavailable/
not avail.
available rotary no
--- linear possible
available not
available
rotary rotary rotary rotary possible
rotary --- possiblerotary rotary
--- linear possible
rotary --- possible
rotary
available/
not avail.
available
rotary linear
--- linear possible
linear not
available
not
available
linear --- --- linear not possible
Fig. 5-101: Useful scaling type settings depending on mechanical drive system
and measuring systems