7-8 Operating Modes MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Diagnostic Messages and Monitoring Functions
Diagnostic Status Message
The activated "torque/force control" mode is displayed by the following
diagnostic message:
A0100 Drive in TORQUE control
Monitoring Functions
Monitoring functions in torque/force control:
The value of parameter S-0-0036, Velocity command value is limited
to
S-0-0091, Bipolar velocity limit value. If the value in S-0-0036 is
higher than the value in S-0-0091, the E2063 Velocity command
value > limit S-0-0091 warning is generated.
7.3 Velocity Control
Brief Description
In the "velocity control" mode a velocity command value is preset for the
drive. The velocity command value is limited by ramps and filters.
torque/force
command value
effective
velocity command
value
DF0026v1.fh7
M
velocity command
value
command value adjust-
ment for velocity loop
velocity loop
current loop
Fig. 7-4: "Velocity control" block diagram
an external velocity command value (sum of S-0-0036, Velocity
command value and S-0-0037, Additive velocity command value)
is preset via analog inputs or master communication interface
(SERCOS, field bus, ...)
selection of predefined and internally stored velocity command value
steps (fixed values) via digital inputs (e.g. jogging forward/backward,
feeding, setting up, ...)
window comparator for masking critical velocity ranges in the
command value channel (e.g. machine resonances) with
corresponding acceleration adjustment (cf. P-0-1209)
ramp generator with separately adjustable two-stage acceleration and
deceleration limits of the preset velocity command value; switching
from ramp 1 to ramp 2 is done with selectable velocity and run-up stop
that can be parameterized
velocity control via a digital PI loop with extensive filter measures
monitoring the command velocity and actual velocity for exceeding
parameter S-0-0091, Bipolar velocity limit value
smoothing of velocity control loop difference via filter that can be
parameterized
E2063 Velocity command value >
limit S-0-0091
Features
Base package of all variants