MPH-02, MPB-02, MPD-02 Drive Functions 8-89
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Overview of Available Libraries
Note: This chapter only gives a short explanation of the basic
functions or libraries. The functional details are described in
the separate documentation "Rexroth IndraMotion MLD-S".
There are the following data channels to the drive available:
parameter functions, function blocks and cycl. parameters
library Base_MPH02.lib
real-time channel for consistent data exchange
(a maximum of 4 parameters per direction)
library DSP_MPH02.lib
drive-specific motion blocks according to PLC-Open
library MXMotion.lib
diagnosis, error handling and axis addressing (for multi-axis
operation possible in the future)
library CommonTypes.lib
global registers for data exchange of variables via master
communication
Additionally for drive-internal functions (not user-relevant):
library Internal_MPH02.lib
The Base_MPH02.lib library contains important data types, basic
firmware modules and cyclic parameters as direct variables (system-wide
variables).
General functions:
ATAN2
MX_fGetFreeTicks
MX_fGetHighResTime
MX_fHighResTimerTicks_to_us
Blocks/functions for drive control:
MX_Command
MX_Power
MX_Reset
MX_SetControl
MX_SetDeviceMode
MX_SetOpMode
Functions for diagnosis:
MX_fGetDriveWarning
MX_fSetDriveWarning
MX_fSetDriveError
Blocks/functions for parameters:
MX_fReadParamDINT
MX_fReadStringParam
MX_fWriteParamDINT
MX_fWriteStringParam
MX_ReadParamDINT
MX_WriteParamDINT
Base_MPH02.lib