D7212GV2 | Program Entry Guide | 6.0 GV2AUX EN | 120
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
RPS IP Address 2
Default: 0
Selection: 0 to 255
Refer to
RPS IP Address 1
.
RPS IP Address 3
Default: 0
Selection: 0 to 255
Refer to
RPS IP Address 1
.
RPS IP Address 4
Default: 0
Selection: 0 to 255
Refer to
RPS IP Address 1
.
RPS Port Number
Default: 7700
Selection: 1 to 65535
This prompt specifies the destination port for outgoing
RPS session requests to the IP address specified in
RPS
IP Address #
.
6.4.2 Using an External Modem
Through the use of a standard, off-the-shelf modem
(capable of communicating at 9600 baud) and a
D9133DC connected directly to the control panel, RPS
can communicate with a D7212GV2 at speeds of up to
9600 baud.
Both the U.S.Robotics V.92 56 K Modem
(model No. 5686, includes V.92 and V.90
56 K standard technology) and the Best
Data Smart One V.92/V.44 56 K External
Data/Fax Modem (model # 56SX-92) are
recommended for use as external modems
(connected to the control panel) based on
compatibility testing by Bosch Security
Systems, Inc.. Other modules were not
tested or were incompatible.
The seven prompts on page 123 help to configure the
requirements necessary to connect an external modem
to a D7212GV2 Control Panel using a D9133DC. This
configuration allows communication with RPS at 9600
baud because data is routed through the SDI bus.
Use a separate phone line if an external
modem is being connected to the control
panel by a D9133DC Direct Connect
Programming Module. If obtaining a
different phone line from the line used by
the control panel is impossible, ensure that
the control panel is wired in front of any
premises phone and the external modem
devices so that full line seizure is
maintained. Also, ensure that the following
items are programmed in Section 2.7 RPS
Parameters on page 28:
Answer Armed = Blank or 0
Answer Disarmed = Blank or 0
RPS Line Monitor = No
RPS Call Back = No
RPS Phone number = Blank
When using an external modem, initialize it
using the following HyperTerminal
procedure on your computer. The
HyperTerminal procedures can vary,
depending upon the operating system.
1. In Windows
®
, open the HyperTerminal
application. Select:
ProgramsAccessoriesCommunications
2. Connect the modem to an available COM port.
3. With the modem connected, select the appropriate
COM port within HyperTerminal. Refer to
Figure 8 on page 121.
4. Set the baud rate of the modem to 9600.
For Best Data Smart One V.92:
Type [A][T][S][3][7][=][9][Enter]
For US Robotics:
Type [A][T][&][N][6][Enter]
For other modems, consult the instructions
provided with the device for the correct text
string.
5. Type [A][T][E][0][Enter]. This eliminates echo,
making all user input from this point forward
invisible on the screen.
6. Type [A][T][&][W][0][Enter] to write the
configuration to modem memory. The modem
profile is saved to a file upon disconnection or
power loss.