D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 56
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Table 24: Keypad Programming Choices
Selection Description
Blank Disable the function panel-wide.
The keypad shows NO
AUTHORITY if you access the
function using a command or the
Function List.
E Enable the function panel-wide. The
function can be executed without
entering a passcode.
P Passcode required. When the
passcode is entered at the keypad,
the control panel checks the user’s
authority level. Refer to Section
2.11.4 Authority Level Selections
on page 61.
Refer to Section 2.11.4 Authority Level
Selections on page 61 for a detailed
description of the functions on the following
pages. These parameters determine only if
the authority level functions are pass-code
protected.
Master Arm Delay
Default: P
Selection:
Blank, E, or P
P
Passcode: Required for all users with
Master Arm Delay enabled for their
authority level.
E
Enable: A user does not need a
passcode to use [COMMAND][1].
Blank Disable Master Arm Delay cannot be
accessed in the function menu or
started with a command even if this
function is enabled for the user’s
authority level.
Function No. Function Name Alternate Keystroke
2 Master Arm Delay [COMMAND][1]
Use this arming function to master arm disarmed
areas. If enabled, the following arming choices are
available to the user with this authority.
Mstr Arm Inst
Default: Blank
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
3 Master Arm Instant [COMMAND][1][1]
Use this arming function to master arm instant areas
that are disarmed. Entry and exit delays are not
provided with this arming function. This causes a
Perimeter and Interior Delay point to act as an Instant
point.
For SIA CP-01 Compliance
This feature is not allowed in SIA CP-01
compliant installations.
Perim Instant
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
4 Perimeter Instant
Arm
[COMMAND][2]
Instant arms all perimeter points with point response
that starts an instant alarm (refer to
P## Pt Response
in Section 4.2 Point Responses on page 84) in the area
where the keypad is assigned. Entry and exit delays
are not provided with this arming function. This
function causes a Perimeter Delay point to act as a
Perimeter Instant point.
For SIA CP-01 Compliance
This feature is not allowed in SIA CP-01
compliant installations.
Perim Delay
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
5 Perimeter Delay
Arm
[COMMAND][3]
Delay arms all Perimeter points in the area where the
keypad is assigned. Entry and exit delays are provided
with this Arming function. This function does not
cause a Perimeter Instant point to act as a Delay point.