D7212GV2 | Program Entry Guide | 6.0 GV2AUX EN | 131
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Swinger Count
Default: 1
Selection:
1, 2, 3, or 4
1, 2 Number of fault or trouble bypasses
allowed per hour for SIA CP-01
compliance.
3 Optional fault count
4 Value used for backward compatibility
with previous control panel operation.
When a point has
P# Swinger Byps
set to Yes, the
value set in
Swinger Count
determines the number of
times the point is faulted erroneously within an hour
before it is automatically bypassed.
For SIA CP-01 Compliance:
P## Swinger Byps
can be Yes or No.
If
P## Swinger Byps
is Yes,
Swinger Count
must be
1 or 2.
Remote Warning
Default: Yes
Selection:
Yes or No
Yes The system uses the Alarm Bell output
to annunciate the arming and
disarming of an area through remote
software, or a remote arming device
such as a key switch or key fob.
No No remote warning occurs to
annunciate the arming and disarming
of an area through remote software, or
a remote arming device such as a key
switch or key fob.
Upon remote arming, the output pulses on for 2 sec.
Upon remote disarming, the output pulses on, off, on,
off for 2 sec each.
For SIA CP-01 Compliance
Remote Warning
must be set to Yes.
CrystalTime Adj
Default: No
Selection:
Yes or No
Yes Set the clock time control on the
control panel to the on-board crystal
frequency.
No Do not set the clock time control on
the control panel to the on-board
crystal frequency.
When set to Yes, the control panel switches its clock
time control from the traditional AC frequency to the
on-board crystal frequency. This prompt replaces the
alternate function that was enabled by setting the
Silent Alarm Relay for Area 4 to a value of 60.
Perimeter Relay
Default: No
Selection:
Yes or No
Yes Change the function of the area-wide
fail-to-close relays to follow the
perimeter armed states of their areas.
No The area-wide fail-to-close relay
operates normally.
When set to Yes, the
A# Fail to Close
relay becomes
an area-wide perimeter armed relay. This relay is
activated when all areas assigned to the same relay
have perimeter points that are armed. This prompt
replaces the alternate function that was enabled by
setting the Silent Alarm Relay for Area 7 to a value of
63.
Early Armed Relay
Default: No
Selection:
Yes or No
Yes Change activation of Area Armed or
Perimeter Armed Relay to the
beginning of the exit delay time.
No Maintain the activation of Area Armed
or Perimeter Armed Relay at the end
of the exit delay time.
When this prompt is set to Yes, the Area Armed or
Perimeter Armed Relay activates at the beginning of
the exit delay time. This prompt replaces the alternate
function that was enabled by setting the Silent Alarm
Relay for Area 8 to a value of 64.